streak camera
rus eng
streak camera
Streak cameras and frame tubes Streak camera and frame cameras Optical pulsed generators Digital readout systems Accessory equipment

PIM-104

The streak tube is intended for low-illuminating fast running processes image registration in streak and multiframe modes. It has a photocathode applied on uviol glass or a fiber-optic disk, focusing electrodes, a compensated electron shutter of deflective type, two pairs of plates that deflect the image in mutually transverse directions, one or two MCP and a blue/green screen applied on a fiber-optic disk

 

Main parameters

Photocathode type S-20
Range of spectral sensitivity, nm: 
- input window applied on uviol glass
- input window applied on a fiber-optic disk

230 – 850
380 – 850
Maximum photocathode sensitivity, mА/W 
Maximum gain, W/W: 
- with one MCP 
- with two MCP
Dimensions of the photocathode useful area, mm х mm
≥ 20 

≥ 104 
≥ 106 
8 x 8
Diameter of the screen useful area, mm
magnification, a.u.
38 
2
Spatial resolution f the photocathode in a statistical mode, l.p./mm: 
- with one MCP 
- with two MCP
Photocathode useful voltage, kV

≥30 
≥ 20 
7,5
Blanking voltage of the electron shutter, V 
Sensitivity of both pairs of deflecting plates, mm/V
Limiting temporal resolution of the tube operated in a streak mode, ps
≤ 400 
≥ 0,06 
≤ 100
Streak tube dimensions, mm length 365
width / max. diameter 130 / 100
Weight, kg ≤ 1,5